Annual Cavern Report (Form H-10H)
Items 1 through 11--Identification
- These items are computer generated from the current Commission database. Note changes by crossing through incorrect information and writing the correct information above it.
- You may obtain additional copies from the RRC website using the Interactive Data / Public H-10 Query.
Item 12--Reporting cycle
- The reporting cycle is pre-printed on the form.
- You may check a particular field's reporting cycle using the Interactive Data / Public H-10 Query.
- Lists the months and year for which monitoring data must be provided.
Item 13--Operating injection pressures
- Answer in accordance with the plain meaning of this prompt. In addition to the plain meaning conferred by this prompt, the following discussion should refine the answer.
- Report maximum recorded annulus pressure in the “Hydrocarbon or Gas” column for each reporting month.
- This information may not be applicable for a brine mining permit pursuant to Statewide Rule 81 if the cavern does not have a roof blanket
- This information is mandatory for a storage permit under Statewide Rules 95 or 97 as required by sections (n)(1)(B) of these rules.
- Report the maximum recorded hanging string pressure in the “Brine” column for each reporting month.
- Technical staff will review the operation if any reported pressure exceeds the authorized pressure.
- The maximum allowed pressure for a permit pursuant to Statewide Rule 81 may be set both by an explicit value given in the permit, and by the restriction that the maximum allowed pressure may not result in the gradient at the lowermost casing shoe exceeding 0.8 psi/ft. The operation of the well must comply with both.
- The maximum allowed pressure for a permit pursuant to Statewide Rule 95 may be set by an explicit value given in the permit, and by the restriction that the maximum allowed pressure may not result in the gradient at the lowermost casing shoe exceeding 0.8 psi/ft. The operation of the well must comply with both.
- The maximum allowed pressure for a permit pursuant to Statewide Rule 97 may be set by an explicit value given in the permit, and by the restriction that the maximum allowed pressure may not result in the gradient at the lowermost casing shoe exceeding 0.85 psi/ft. The operation of the well must comply with both.
- Significant violations may be grounds for termination of the permit.
Item 14--Injected volumes
- Answer in accordance with the plain meaning of this prompt. In addition to the plain meaning conferred by this prompt, the following discussion should refine the answer.
- Injection volume must be reported in barrels (BBL) of liquid or thousand standard cubic feet (MCF) of gas.
- Injection should be reported as positive values. Withdrawal should be reported as negative values.
- The “Hydrocarbon” and “Gas” columns are not applicable for permits pursuant to Statewide Rule 81.
Item 15—Total Cavern Capacity
- Answer in accordance with the plain meaning of this prompt. In addition to the plain meaning conferred by this prompt, the following discussion should refine the answer.
- Report the most accurate available value for the total cavern capacity as of the end of the reporting cycle. The total cavern capacity is the total dissolved void space within the salt formation.
- The value must be entered in units of thousands of barrels (MBBL)
Item 16—Maximum Volume of Hydrocarbon or Gas Stored During Year
- Answer in accordance with the plain meaning of this prompt. In addition to the plain meaning conferred by this prompt, the following discussion should refine the answer.
- For permits pursuant to Statewide Rule 95, report the maximum volume of liquid hydrocarbon stored during this reporting cycle, in units of thousands of barrels (M BBL)
- For permits pursuant to Statewide Rule 97, report the maximum volume of gas stored during this reporting cycle, in units of thousands of standard cubic feet (MCF)
- For permits pursuant to Statewide Rule 81, this item is not applicable.
Item 17—Hydrocarbon or Gas Storage Inventory as of Last Month of Reporting Year
- Answer in accordance with the plain meaning of this prompt. In addition to the plain meaning conferred by this prompt, the following discussion should refine the answer.
- For permits pursuant to Statewide Rule 95, report the volume of liquid hydrocarbon in inventory as of the end of this reporting cycle, in units of thousands of barrels (M BBL)
- For permits pursuant to Statewide Rule 97, report the volume of liquid hydrocarbon in inventory as of the end of this reporting cycle, in units of thousands of standard cubic feet (MCF)
- For permits pursuant to Statewide Rule 81, this item is not applicable.
- Item 17 for the present reporting cycle is expected to be equal to (or approximately equal to) item 17 from the previous reporting cycle, plus net injected product (from item 14) during the present reporting cycle, and minus net withdrawn hydrocarbon product (from item 14) during the present reporting cycle.
Item 18—Well Status Code No.
- The status codes 1 through 7 are established by the Form H-10H instructions, and are described by the H-10H instruction as follows:
1 - Authorized for storage, but not yet drilled
2 - Drilled, but not yet in storage service
3 - Active storage service
4 - Alternative monitoring (out of storage service)
5 - Temporarily abandoned/shut-in
6 - Plugged
7 - Other (specify)
- The selection of the status code for certain scenarios is expected as follows:
- Always select code “7” for a permit pursuant to Statewide Rule 81.
- Select code “2” for a well permitted under Statewide Rule 95 or 97 that is undergoing leaching during this reporting cycle.
- Select code “4” for a well permitted under Statewide Rule 95 or 97 that is operating under temporary alternative monitoring status under section (o) of these rules.
- Select code “5” for a well permitted under Statewide Rule 95 or 97 that is operating under permanent alternative monitoring status under section (o) of these rules.
Item 19—Do other wells enter this cavern?
- Answer in accordance with the plain meaning of this prompt.
- An answer of Yes is expected if another as-drilled well is in communication with the dissolved void space accessed by the subject well.
Item 20—What is currently being stored?
- Answer in accordance with the plain meaning of this prompt. In addition to the plain meaning conferred by this prompt, the following discussion should refine the answer.
- For permits pursuant to Statewide Rule 81, this item may be omitted.
Item 21—Were any LPG aboveground vessels or loading racks installed during the last year?
- Answer in accordance with the plain meaning of this prompt. Note that any answer given to this item does not supersede the applicability of any other rule.