W-10 Record
W-10 COBOL Record Layout
W-10 Record Data Dictionary
W-10 Record Position Length Data Item Data Type Notes 1 - 6 6 Operator Number Numeric 7 - 9 3 Report Type Alphanumeric Must be 'W10' 10 - 11 2 District Numeric Must be one of the following: 01,02 03,04,05,06,07,08 09,10,11,13,14 12 1 Record Type Alphanumeric Must be 'R' 13 - 18 6 Filler Alphanumeric Must be spaces 19 - 50 32 Field Name Alphanumeric 51 - 83 33 Filler Alphanumeric Must be spaces 84 - 88 5 Lease Number Numeric 89 1 Filler Alphanumeric Must be spaces 90 - 95 6 Well Number Alphanumeric 96 - 98 3 Filler Alphanumeric Must be spaces 99 - 104 6 Effective Date Numeric In Year (without the Century), Month, Day order 105 - 112 8 Field Number Numeric 113 - 144 32 Lease Name Alphanumeric 145 1 Producing Method Alphanumeric 146 - 147 2 Filler Alphanumeric 148 - 153 6 Date Tested Numeric In Year, Month, Day order 154 - 160 7 Daily Oil Numeric This number has an explicit decimal in the sixth position and must be provided in that exact position. Example: 12345.7 161 - 164 4 Daily Water Numeric 165 - 171 7 Daily Gas Numeric 172 - 200 29 Filler Alphanumeric 201 - 225 25 Remarks Alphanumeric 226 1 Filler Alphanumeric 227 1 Shut-in Flag Alphanumeric 228 - 400 173 Filler Alphanumeric W-10 COBOL Record Layout The position numbers on the right hand side give the beginning position for that data item. 01 W10-REPORT-RECORD. POSITION 03 W10-RECORD-ID. 05 W10-OPERATOR-NO PIC 9(6). 1 05 W10-REPORT-TYPE PIC X(3). 7 88 W10-REPORT VALUE 'W10'. 05 W10-DISTRICT PIC 9(2). 10 88 W10-VALID-DISTRICT VALUE 01,02,03, 04,05,06,07,08, 09,10,11,13,14 05 W10-RECORD-TYPE PIC X(1). 12 88 W10-REPORT-REC VALUE 'R'. 05 FILLER PIC X(6). 13 05 W10-FIELD-NAME PIC X(32). 19 05 FILLER PIC X(33). 51 05 W10-LEASE-NUMBER PIC 9(5). 84 05 FILLER PIC X(1). 89 05 W10-WELL-NUMBER PIC X(6). 90 05 FILLER PIC X(3). 96 05 W10-EFFECTIVE-DATE. 07 W10-EFFECTIVE-YEAR PIC 9(2). 99 07 W10-EFFECTIVE-MONTH PIC 9(2). 101 07 W10-EFFECTIVE-DAY PIC 9(2). 103 03 W10-FIELD-NUMBER PIC 9(8). 105 03 W10-LEASE-NAME PIC X(32). 113 03 W10-PRODUCING-WELL-INFORMATION. 05 W10-PRODUCING-METHOD PIC X(1). 145 88 W10-FLOWING VALUE 'F'. 88 W10-PUMPING VALUE 'P'. 88 W10-GAS-LIFT VALUE 'G'. 88 W10-SWABBING VALUE 'S'. 05 FILLER PIC X(2). 146 05 W10-DATE-TESTED. 10 W10-TEST-YEAR PIC 9(2). 148 10 W10-TEST-MONTH PIC 9(2). 150 10 W10-TEST-DAY PIC 9(2). 152 05 W10-DAILY-OIL. 10 W10-DAILY-OIL-WHOLE PIC 9(5). 154 10 W10-DAILY-OIL-DECIMAL PIC X(1). 159 10 W10-DAILY-OIL-FRAC PIC 9(1). 160 05 W10-DAILY-WATER PIC 9(4). 161 05 W10-DAILY-GAS PIC 9(7). 165 03 FILLER PIC X(29). 172 03 W10-REMARKS PIC X(25). 201 03 FILLER PIC X(1). 226 03 W10-SHUTIN-FLAG PIC X(1). 227 88 W10-WELL-IS-SHUTIN VALUE 'Y'. 88 W10-WELL-IS-NOT-SHUTIN VALUE 'N'. 03 FILLER PIC X(173). 228 W-10 Record Data Dictionary W10-OPERATOR-NO The operator number assigned to the company by the RRC. Taken from the Organization Report (Form P-5). W10-REPORT-TYPE Must be 'W10' for W-10 reports. W10-DISTRICT The RRC district in which the well is located. See DR-DISTRICT for further details. W10-RECORD-TYPE Must be 'R' for report records. W10-FIELD-NAME The field name exactly as shown on the RRC proration schedule. W10-LEASE-NUMBER Must be a valid five-digit, RRC-assigned oil lease number. W10-WELL-NUMBER Must be a six-character alphanumeric well number exactly as shown on the RRC proration schedule. W10-EFFECTIVE-DATE This is the date the report is effective in year, month, day format. For original surveys the day should always be one (1). W10-FIELD-NUMBER The RRC assigned identifying number of the field in which the oil well is currently located. W10-LEASE-NAME The lease name exactly as shown on the RRC proration schedule. W10-PRODUCING-METHOD The production method of the oil well. CODE METHOD Space Non-Producting Well F Flowing P Pumping G Gas Lift S Swabbing W10-DATE-TESTED The date the well was tested in year, month, day order. W10-DAILY-OIL The daily oil potential for the well in barrels. W10-DAILY-WATER The daily water potential for the well in whole barrels. W10-DAILY-GAS The daily casinghead gas potential for the well in MCF. W10-REMARKS Any comment desired. W10-SHUTIN-FLAG Indicates if the well is shut-in. Value as 'N' if the well is not shut-in or 'Y' if the well is shut-in.